SCALE
Press the SCALE key to view the scale function key options:
SCALE KEY PROGRAMMING
DESC : SCALE
KEY DISABLE N
UNDER MGR CONTROL N
KEY IS MAN. ENTRY N
TARE-WEIGHT COMP. N
WEIGHT SYM FOR MAN.
(0:LB 1:KG 2:OZ) 0
Press CASH from the last field or press PAGE DOWN to view the second page of
scale function key options:
SCALE KEY PROG.
ALLOW DOLLAR ENTRY N
W/O SCALE ON
SCALEABLE ITEM
Press CASH from the last field to return to the FUNCTION KEY PROGRAM
screen, or press CLEAR at any time to return to the FUNCTION KEY PROGRAM
screen without saving changes.
SCALE Key Program Notes
Option Entry Description
DESC Alpha-numeric
12 character
You can program a unique descriptor. The default descriptor
is SCALE.
KEY DISABLE Y or N Select Y to disable this function.
UNDER MGR
CONTROL
Y or N
Select Y if you do not want the operator to use this function
in REGISTER mode. When selected, the function is allowed
only in the X control lock position.
KEY IS MAN.
ENTRY
Y or N Select Y if you wish to scale key to enter a manual weight.
Select N if you wish to automatically recall the weight from
the attached scale.
TARE-WEIGHT
COMP.
Y or N Select Y if you wish to enforce the subtraction of a tare
weight on the scale entry.
WEIGHT SYMBOL
FOR MAN
Y or N Select Y if you wish to use the weight symbol Kg (kilogram)
for weights entered manually or OZ for ounce measurements.
ALLOW DOLLAR
ENTRY W/O SCALE
ON SCALEABLE ITEM
Y or N
If N, you must use the scale to register scalable PLU items. If
Y, you can either register scalable items by weight extension,
or by price entry.