PN 9001024
Rev. B Jan. 2000
Page 3-3
SATO CL608 & CL612 SERVICE MANUAL
SECTION 3 – Interface Specifications
Multi Job Buffer (Cont.)
3-4 RS232C Serial Interface
General Specifications
IICSAsuonorhcnysA
noitacinummocxelpud-flaH
lortnoCwolFerawdraHysuB/ydaeR
lortnoCRTD,02niP
noitidnoCrorrESTR,4niP
lortnoCwolFerawtfoSffO-X/nO-X
)esnopseR/QNE(noitacinummoclanoitceriD-iB
etaRnoissimsnarTataD
spb00291dna0069,0084,0042
tamroFretcarahC
)dexif(tiBtratS!
)elbatceles(stibatad8ro7
)elbatceles(ytiraPoNronevE,ddO
)elbatceles(stibpotS2ro1
The receiving buffer will not be able to receive more data again until a Buffer
Available condition occurs. This takes place when the receiving buffer has
emptied so that only 56K bytes of data are being held (8K bytes from being
full). At this time, DTR will go high or an X-On is sent to tell the host that it
can again receive data. See Fig. 3-2
All printer error conditions, (i.e., label out, ribbon out), will cause the printer
to go busy (DTR low or X-Off) until the problem is corrected, and the
printer is placed on-line. The printer will also be busy if taken off-line from the
front panel.
Fig. 3-2
DTR Low or
X-Off
Buffer Available
DTR High or
X-On
0
56K 64K
1 Start Bit (fixed)
7 or 8 data bits (selectable)
Odd, Even or No Parity (selectable)
1 or 2 Stop bits (selectable)