Back to top 2 Operation and Con guration
S84NX/S86NX Service Manual
33
2.3.8 Factory O set
Select [Tools]
>
[Service]
>
[O set].
Correct the o set position.
Set the o set value “+” to move the stop position in the direction opposite to the media feed direction
and value “–” to move the stop position in the media feed direction.
O set position refers to the tear-o position, cut position and dispense stop position.
Setting range: –99 to 99 dots (Default: 0 dots)
Print head (Thermal head)
Media feed
direction
Adjustment of “+” value
(+99 dots)
No adjustment (0 dots)
Adjustment of “–” value
(–99 dots)
Note
The actual o set position is the sum of the o set value set here and the o set value set for print
position, in Service menu.
When you change the o set value in the Service menu, the o set value set at factory shipment also
changes.