Back to top 2 Operation and Confi guration
S84NX/S86NX Service Manual
33
2.3.8 Factory Off set
Select [Tools]
>
[Service]
>
[Off set].
Correct the off set position.
Set the off set value “+” to move the stop position in the direction opposite to the media feed direction
and value “–” to move the stop position in the media feed direction.
Off set position refers to the tear-off position, cut position and dispense stop position.
Setting range: –99 to 99 dots (Default: 0 dots)
Print head (Thermal head)
Media feed
direction
Adjustment of “+” value
(+99 dots)
No adjustment (0 dots)
Adjustment of “–” value
(–99 dots)
Note
• The actual off set position is the sum of the off set value set here and the off set value set for print
position, in Service menu.
• When you change the off set value in the Service menu, the off set value set at factory shipment also
changes.