3 Checking and Performing Printer Adjustments
3.3.2 Checking the Ribbon End Function
1 min
1
Remove the ribbon if you have loaded in the product.
2
Power on the printer.
3
Select [Settings]
>
[Printing]
>
[Printing Mode]
>
[Use Ribbon].
4
Press the Back button on the operator panel to change the printer to o ine mode.
5
Select [ ] (right select button) and check that the buzzer sounds and the error message
is displayed.
6
If no error occurs, replace the sensor.