S84NX/S86NX Service Manual
43
Back to top
3 Checking and Performing Printer Adjustments
Print Head (Thermal Head)
Platen Roller
If the counter value is close to the guaranteed value, check the part and, if it is worn out, replace it
with a new one.
Refer to
4.3.1 Replacing the Print Head
Refer to
4.4.1 Replacing the Platen Roller
3.2.1 Checking and Cleaning the Exterior
1 min
Clean the LCD and exterior.
1
Check that no cracks or breakage appear on the exterior before cleaning.
2
Check that the touch panel works properly.
3
Check that the power/home button works properly.
3.2.2 Blowing Air on the PCBs
1 min
Blow air on the PCB to remove dust or dirt.
CAUTION
Before cleaning the PCB, make sure to power o the printer. Next, unplug the AC power cord.
1
Is the connector loose?
2
Is the screw loose?
3
Is the cable caught?
4
Is the gear broken or worn out?