Back to top 4 Replacement
S84NX/S86NX Service Manual
61
3
Wiring route
A
Ribbon motor RW cable
B
Ribbon motor UW cable
• Make sure that the ferrite core (
1
) is attached with reference to the cable tie position of both the
Ribbon motor RW cable (A) and Ribbon motor UW cable (B).
• Make sure that the Ribbon motor RW cable (A) and Ribbon motor UW cable (B) run through the
two CLAMPs.
LH type
RH type
CLAMP
A
B
1
Cable ties CLAMP
A
B
1
Cable ties
• Make sure that the Ribbon motor RW cable (A) and Ribbon motor UW cable (B) run through the
saddle-1.
• Make sure that the ferrite core (
2
) is attached to only the Ribbon motor RW cable (A).
• Make sure that the ferrite core (
2
) is placed between the saddle-1 and saddle-2.
• Make sure that the Ribbon motor RW cable (A) and Ribbon motor UW cable (B) run through the
saddle-2.
LH type
RH type
2
Saddle-1
Saddle-2
B
A
Saddle-1
Saddle-2
2
A
B