20
Operating Instructions – MOVIFIT® basic
5
Power bus connection (line cable)
Electrical installation
3. Pull both locking tabs to the outside and tilt up the upper part of the FieldPower
®
con-
tact module.
4. Loosen the 4 screws and remove the strain relief brackets.
Remove the two cable seals.
5. Remove the sheath of the line cable with a suitable stripping tool.
2839866123
2839868043
2839869963
Line cable Stripping tool Strip length
Round cable AM 16 130 mm
Flat cable AMF 6/10 120 mm