MX-M316N SIMULATION 6 – 39
Code descriptions
List of destination groups
OHL_US OHP
PAPER
OHP-TH_US set value 70 - 220 190 195 190 195 195 195
PHL_UM ENV
PAPER
Envelope TH_UM set value 70 - 220
205 205 205 205 210 210
QHL_US ENV
PAPER
Envelope TH_US set value 70 - 220
205 205 205 205 210 210
R HL_UM E-STAR Preheating TH_UM set value 70 - 220
95 95 95 95 95 95 95 95 95 95 95 95
S HL_US E-STAR Preheating TH_US set value 70 - 220
95 95 95 95 95 95 95 95 95 95 95 95
T HL_UM PRE-JOB TH_UM set value when
recovery from Warm-Up
70 - 220
180 180 190 190 180 180 190 190 180 180 190 190
UHL_UM
WARMUP_120L
TH_UM set value when Warm-
Up at 120 degree C or below
70 - 220
180 180 190 190 180 180 190 190 205 205 205 205
VHL_US
WARMUP_120L
TH_US set value when Warm-
Up at 120 degree C or below
70 - 220
180 180 190 190 180 180 190 190 205 205 205 205
WLO_WARMUP_TIM
E
U, V applying time (Timer from
completion of Ready)
0 - 255
0 0 0 0 0 0 0 0 0 0 0 0
XHL_UM
WARMUP_120H
TH_LM set value when Warm-
Up at 120 degree C or above
70 - 220
180 180 190 190 180 180 190 190 180 180 190 190
YHL_US
WARMUP_120H
TH_US set value when Warm-
Up at 120 degree C or above
70 - 220
180 180 190 190 180 180 190 190 180 180 190 190
Z HI_WARMUP_TIM
E
X, Y applying time (Timer from
completion of Ready)
0 - 255
0 0 0 0 0 0 0 0 0 0 0 0
AA HI_WU_FM_ON_T
MP
FM prior rotation start TH_US
when Warm-Up at alpha
degree C or above
0 - 220
0 0 0 0 0 0 0 0 0 0 0 0
AB HI_WU_END_TIME Warm-Up completion time
when Warm-Up at alpha
degree C or above
0 - 60
18 18 18 18 18 18 18 18 18 18 18 18
AC HI_WU_JOB_SET_
TMP 1
Job enable TH_UM
temperature 1 when Warm-Up
at alpha degree C or above
30 - 220
180 180 190 190 180 180 190 190 205 205 205 205
AD HI_WARMUP_BOR
DER
Threshold value alpha to which
U - W is applied
1 - 119
60 60 60 60 60 60 60 60 60 60 60 60
AE LO_WU_JOB_SET
_TMP 1
Job enable TH_UM
temperature 1 when Warm-Up
at alpha degree C or below
70 - 220
180 180 190 190 180 180 190 190 205 205 205 205
AF JOBEND_FUMON_
TIME
After rotating time when a job is
completed
0 - 60
0 0 0 0 0 0 0 0 0 0 0 0
AG HI_WU_JOB_SET_
TMP 2
Job enable TH_UM
temperature 2 when Warm-Up
at alpha degree C or above
70 - 220
180 180 190 190 180 180 190 190 180 180 190 190
AH LO_WU_JOB_SET
_TMP 2
Job enable TH_UM
temperature 2 when Warm-Up
at alpha degree C or below
70 - 220
180 180 190 190 180 180 190 190 180 180 190 190
Item/Display Content
Setting
range
Default value
26cpm 31cpm 35cpm
Group A Group B Group A Group B Group A Group B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
SW-
A
SW-
B
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
Group Destination
Group A U. S. A CANADA INCH - -
Group B EUROPE U. K AUS. AB_A AB_B