3.5 Encoder Safety Precautions for Installation, Operation and Maintenance
The ATM60/ATM90/KHK53 encoders must only be fitted or main-
tained when free from voltage. Consequently, for any electrical or
electronic devices, machine and system parts linked to installa-
tion, operation or maintenance, the voltage must previously have
been switched off. Also check that they are voltage-free.
Cabling, earthing, screening and overvoltage protection are of
particular importance.
Check whether switching off devices, machines or system parts
causes dangers.
If necessary, place warning signs to prevent unauthorised per-
sons from entering the danger area.
The correct functioning of safety features shall be checked (e.g.
emergency stop).
EMC-compliant earthing and screening must be performed with
particular care, to ensure satisfactory operation of the devices.
The safe assembly of all components must be checked prior to
switching back on.
Avoid impacts on shaft and collet.
Programs which frequently use Explicit Messages, to write pa-
rameters to the EEPROM (non-volatile memory) of the encoders,
should be avoided. This could significantly reduce the lifetime.
During commissioning of the encoders via a configuration tool,
there must be no connection to a running network.