Page #69 background imageLoading...
Page #69 background image
Encode
r
Mountin
and Connection
Dec 2021
ATM60 / ATM90 / KHK53 67
10.5 Status/Display Information
The devices have two LEDs displaying the status information.
LED Zustand Erklärung
green Operating
voltage
OFF Device is not – or not sufficiently – supplied with voltage.
ON Operating voltage is applied –-Operating Mode.
red Bus activity OFF
Valid data communication (Data_Exchange_Mode)
(C-1)
ON
NO valid data communication --- Data_Exchange_ Mode
was not started or cancelled:
- during the configuration sequence
- due to incorrect parameter data or configuration data
- due to incorrect hardware settings (bus termination,
address, pin-out, cable breakage, ...).
(C-1)
Valid data communication only means that master and slave can communicate with
one another via telegrams. It does not mean that the
data within the remote tele-
grams is also correct --- e.g. incorrect position value, incorrect offset, ... .

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK ATM60 and is the answer not in the manual?

SICK ATM60 Specifications

General IconGeneral
Protection ratingIP65
Housing materialAluminum
Measuring range0 to 360 degrees
InterfaceSSI, Incremental
Operating temperature+70 °C
Protection classIP65
Shaft diameter6 mm, 10 mm
Supply voltage10 V DC ... 30 V DC
Shaft typeSolid shaft
Storage temperature+85 °C
Power supply10 V DC ... 30 V DC
Current consumption< 150 mA