Chapter 6 Operating Instructions
C4000 Palletizer Std./Adv.
C4000 Fusion
66 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8012249/YT69/2016-02-25
Subject to change without notice
Mounting
6.3.2 Minimum distance to reflective surfaces
The light beams from the sender may be deflected by reflective surfaces. This can result in
failure to identify an object.
All reflective surfaces and objects (e.g. material bins) must therefore be located at a mini-
mum distance a from the protective field of the system. The minimum distance a depends
on the distance D between sender and receiver.
The field of view of the sender and receiver optics is identical.
How to determine the minimum distance from reflective surfaces:
Determine the distance D [m] senderEreceiver.
Read the minimum distance a [mm] from the graph:
If it is not possible to maintain the minimum distance from reflective surfaces, there are
ways of reducing the risk of reflections and the resulting resolution. To check whether
these measures are sufficient to adequately reduce the residual risk, you must perform a
risk analysis. For further information, please contact your local SICK representative.
Fig.
39
:
Minimum distance to
reflective surfaces
Note
Fig.
40
:
Graph, minimum
distance from reflective
surfaces
Note
Reflective surface
Minimum distance a
Distance D sender
receiver