Technical specifications
12 Technical specifications
12.1 Data sheet
Minimum Typical Maximum
General system data
Protective field length, depending
on type
300 mm to 1800 mm
Resolution, depending on type 20 mm, 30 mm or 40 mm
Protective field width
C4000 Fusion 1.5E19 m 1.5E21 m
6)
C4000 Palletizer 0.5 E6 m 0.5E7 m
6)
Protection class (EN 50178)
7
)
III
Enclosure rating IP 65 (EN 60529)
Supply voltage V
S
on the
device
8)
19.2 V 24 V 28.8 V
Residual ripple
9)
± 10%
Synchronisation Optical, without separate synchronisation
10)
Type Type 4 (IEC 61496E1)
Category Category 4 (EN ISO 13849E1)
Performance Level
1
1)
PL e (EN ISO 13849E1)
Safety integrity level
11)
SIL3 (IEC 61508)
SILCL3 (EN 62061)
PFHd (mean probability of a
dangerous failure per hour)
1.50 × 10
–8
T
M
(mission time) 20 years (EN ISO 13849)
Power-up delay of sender and
receiver before ready
8 s
6)
On the utilisation of this protective field width, it must be expected the orange LED will illuminate (cleaning or
realignment required). The system then only has a reserve of 30%.
7)
Safety extra-low voltage SELV/PELV.
8)
To meet the requirements of the relevant product standards (e.g. IEC 61496E1), the external voltage supply
for the devices (SELV) must be able to withstand a brief mains failure of 20 ms as required by EN 60204E1.
9)
Within the limits of V
S
.
10)
During switching on with the aid of the first or last beam, after that with any beam.