Chapter 9 Operating Instructions
C4000 Palletizer Std./Adv.
C4000 Fusion
88 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8012249/YT69/2016-02-25
Subject to change without notice
Configuration
9 Configuration
9.1 Default delivery status
As delivered the C4000 is configured as follows:
restart interlock: Internal
external device monitoring (EDM): Deactivated
multiple sampling: 2 times
C4000 Palletizer Standard
goods detection
object size: 500 mm to protective field length – 150 mm
object size monitoring
scanning range: 0.5E6 m
reduced resolution: 2 beams
beam coding: Code 1
C4000 Palletizer Advanced
pallet detection
– 2E5 objects
– maximum object size 240 mm
reduced resolution: 3 beams
scanning range: 0.5E6 m
beam coding: Code 1
C4000 Fusion
protective operation
reduced resolution: none
scanning range: 1.5E6 m
beam coding: Code 1
Check the functions configured prior to commissioning!
Check whether the functions configured as delivered match the requirements for your
application. Change the functions with the aid of the CDS if necessary.
WARNING