Operating Instructions Chapter 4
C4000 Palletizer Std./Adv.
C4000 Fusion
8012249/YT69/2016-02-25 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 33
Subject to change without notice
Configurable functions
You can configure the bypass function and whether the input is connected equivalent or
complementary in the CDS on the C4000 (receiver).
The connection of the key-operated pushbutton for bypass is described in chapter 7.7
“Key-operated pushbutton for bypass” on page 80.
4.5 Application diagnostic output (ADO)
The C4000 has a signal output (ADO) that can be configured). With the aid of the applica-
tion diagnostic output, the safety light curtain can signal specific states. You can use this
output for a relay or a FPLC.
You must not use the application diagnostic output for safety-relevant functions!
You are only allowed to use the application diagnostic output for signalling. You must never
use the application diagnostic output for controlling the application or with safety-relevant
functions.
The connection can signal one of the following states:
Assignment Application possibilities
Contamination Eases diagnostics in case of contaminated front screen
OSSD status with
delay of [s]
Signals the status of the output signal switching devices. If the
safety light curtain switches to red, then it signals the status
immediately. If it switches to green, then it signals the status only
after an adjustable delay in the range from 0.1 to 3.1 seconds.
Status of the
emergency stop
Signal is present if the button connected to the emergency stop
input on the C4000 has been pressed.
Valid object in the
protective field
Signal is present, if there is at least one valid object in the
protective field (OSSDs activated).
You can configure the application diagnostic output (ADO) in the CDS on the C4000
(receiver).
The electrical connection of a PLC/controller to the application diagnostic output is
described in chapter 7.9 “Application diagnostic output (ADO)” on page 81.
WARNING
configuration for the
application diagnostic output