FLOWSIC100 Operating Instructions
Gas Velocity Monitor
Product Description
28 © SICK MAIHAK GmbH · Germany · All rights reserved 8012513/03-2008
2.3.2 Flange with Pipe
If required, the flanges
with pipe can also be
delivered in advance.
The sender/receiver units are mounted in flanges with pipes, which are available in graded
nominal lengths, different steel types and pitch hole diameters.
Your choice of flange with pipe depends on:
The installation angle, and the wall and insulation thickness of the duct
Determining the nominal length (see Section on Assembly)
Type of sender/receiver unit
Pitch holediameter of flange, pipe diameter
Duct material
Steel types
Fig. 2.16: Flange with pipe
L
L = NL - 12
Type FLSE100 Nominal length in mm Material
S125
St37,
V4A
(others on
request)
S, M, PM, PH 200
S, M, MAC, H, HAC, PR, PM, PH, PHS 350
M, MAC, H, HAC, PR, PRAC, PM, PH, PHS, 550
H, PR, PRAC, PM, PH, PHS 750