FLOWSIC100 Operating Instructions
Gas Velocity Monitor
Product Description
36 © SICK MAIHAK GmbH · Germany · All rights reserved 8012513/03-2008
2.3.4 Connection Cables
The connection cables master (Master FLSE100) and slave (Slave FLSE100) are used to
connect the sender/receiver units with the controll unit MCU. Both cables are available in
different lengths. The connection cable master is marked with a red marker behind the
cable box.
Fig. 2.22: Connection cables
Note: The cables provided on site must fulfill the following requirements (also see Section 3.3.4):
• Effective capacitance core/core less than 110 pF/m
• Min. core cross-section 0.5 mm
2
(AWG20).
We recommend the cable type UNITRONIC Li2YCYv(TP) 2x2x0.5 mm
2
with reinforced outer
sheath (from Lappkabel).
The total length of the cable between connection box and MCU (customer cable) can be up
to 1000 m.
Example: MCU-NWOD010101N
not purged
wide-range power pack
wall housing SICK orange
with display module
without optional analog inputs
with one additional analog output
without optional digital inputs
with additional digital output power
without optional digital outputs low power
with interface module Profibus DP
without special features
Standard cables
Master (Length 5 m , 10 m)
Slave (5 m, 10 m, 50 m)
Customer cable
FLSE100 Slave
Connection cable slave
(Li2YCYv(TP) 2x2x0,5 mm²)
FLSE100 Master
Connection cable master
(Li2YCYv(TP) 3x2x0,5 mm²)