FLT-TERM00001
Weight terminator 8 g (±5 %)
Current consumption 30 mA
Table 53: Data sheet FLT-TERM00001 terminator
10.1.6 PWRI power supply accessory
FLA-PWRI00001
Electrical data
Internal resistance Approx. 50 mΩ
Output current monitoring
Permissible capacitive load Max. 4.7 mF
Permissible inductive load Max. L = 0.74 J/I²
e.g.: 0.18 H @ 2.0 A
2.90 H @ 0.5 A
Overcurrent monitoring
Inrush current within 20 ms Max. 40 A
Surge when switched on with capaci‐
tiv
e load change
Max. 20 A
Table 54: Data sheet PWRI power supply accessory
Characteristic curve
Figure 69: Characteristic curve for PWRI power supply accessory
1
Current characteristic at 40 °C
2
Tolerance
3
Permissible continuous current
4
Emergency shutdown
TECHNICAL DATA 10
8015836/YT10/2016-05-24 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
85
Subject to change without notice