Technical specifications
8.7 Active Management Technology (AMT)
SIMATIC IPC547D
108 Operating Instructions, 06/2011, A5E03473780-01
The sections contain the following information:
AMT settings in the MEBx and in the BIOS setup
Basic configuration of AMT
Further useful notes
8.7.3 Enabling AMT, basic configuration
Procedure
For security reasons, AMT is not enabled on new devices.
To enable AMT, follow these steps:
1. Connect the AMT PC with the LAN.
2. If necessary, first reset AMT to the default status (see section "Unconfigure").
3. To access the BIOS, press the <F2> key while the device is booting.
4. In the Advanced menu, enable "Intel AMT Support", and "Intel AMT Setup Prompt".
5. Exit the BIOS with the <F10> key "Save and Exit". The AMT PC restarts.
6. To access the MEBx, press the <Ctrl+P> keyboard shortcut
7. In the login dialog, enter the standard password "admin".
8. Change the default password. The new password must include the following characters:
In total at least eight characters
One upper case letter
One lower case letter
One number
One of the special characters ! @ # $ % ^ & * @ # $ % ^ & *
Note
The underscore _ and the space characters are valid password characters, however
they do not increase password complexity.
9. Enable "Intel (R) AMT Configuration > Manageability Feature Selection".
10. Enable "Intel (R) ME General Settings > Activate Network Access".