Technical specifications 
  8.7 Active Management Technology (AMT) 
SIMATIC IPC547D 
Operating Instructions, 06/2011, A5E03473780-01 
109 
8.7.4  Advanced settings 
The BIOS and the MEBx contain the most important basic settings for AMT. Additional tools 
are necessary if you want to make more advanced settings. If required, these must be 
downloaded from the relevant manufacturer's site. For information on the options and use of 
these tools, refer to the relevant documentation of the manufacturer.  
●  Manageability Commander and other tools of the Intel DTK (Manageability Developer 
Tool Kit): Programs from the Intel DTK that you can download from the Internet at 
"http://software.intel.com/en-us/manageability". 
●  AMT Web interface: For encrypted connections, the URL of the Web interface is "https:// 
<Fully qualified domain name>:16993" and for unencrypted connections "http://<IP 
address>:16992". 
●  WinRM: A command line program that is part of Windows as of Windows Vista. This tool 
can be downloaded for older Windows versions. 
8.7.5  Resetting with Un-configure 
 
 
Note 
If the AMT PC still has its factory settings, for example has just been purchased, you can 
skip this section. 
 
If you have already configured AMT previously, it is best to discard all the previous AMT 
settings made in the MEBx.  
 
NOTICE 
 
All previous settings in the management engine are deleted. 
Correct operation in the plant may be at risk. 
Note down all the settings in the MEBx. Make the settings again as necessary following 
Unconfigure. 
 
To reset the AMT settings, follow these steps: 
1.  Enable the "Un-configure ME" entry in "Advanced > Active Management Technology 
Support" in the BIOS. 
2.  Exit the BIOS with the <F10> key "Save and Exit". The AMT PC restarts. 
3.  After the restart, a user prompt appears asking whether you really want to discard all the 
settings in the management engine: 
 
4.  Confirm with "Y". On a German keyboard, this means pressing the <Z> key.