Technical specifications
8.6 BIOS description
SIMATIC IPC647D
Operating Instructions, 01/2014, A5E32996306-AA
179
On-screen error messages
On-screen error message
Meaning / tip
Error - Keyboard error
Check whether the keyboard is properly connected.
Error - Keyboard controller error
or no keyboard present
Check whether a functioning keyboard is properly connected. If
this is the case, contact your technical support team.
Error - Keyboard controller error
Keyboard error Contact your Technical Support.
Error - System halted - harddisk
drive (HDD) locked!
Turn off device, remove, HDD interlock and reboot once again.
Error - No MPI/DP interface
detected
PROFIBUS interface defective Contact your Technical Support.
Error - PCH softstrap
programming error: Riser card
may not work correctly
Contact your Technical Support.
Error - PCH softstrap can't be
programmed, descriptor locked:
Riser card may not work
correctly
Contact your Technical Support.
Error - SPI regions are not
locked (ME unlocked)
Contact your Technical Support.
Error - Riser card Taufe does
not match connected hardware
configuration
Contact your Technical Support.
Error - Taufe configuration not
present (Platform = Unknown)
Contact your Technical Support.
Warning - Manufacturer mode
enabled
Contact your Technical Support.
System RAM Failed at offset
Memory error Contact your Technical Support.
Error - CMOS battery failed Battery on the CPU module defective or empty Contact your
Technical Support.
Error - SMART failure detected
on HDD
Hard disk fault: A fault threshold specified by the manufacturer has
been exceeded. Operation of the hard disk is unreliable. The hard
disk has to be replaced. Contact your Technical Support.
No bootable device -- Please
restart system
Possible causes:
No operating system installed
Wrong drive addressed (disk in drive A/B)
Incorrect active boot partition
Incorrect drive entries in SETUP
HDD not connected / defective
Error - Realtime clock has lost
power
Timer block error Contact your Technical Support.
Screen remains dark - cursor
flashes at top left
A data carrier is inserted in the ODD drive. In this case it can take
several minutes until the BIOS power up is continued.