1.2 Design of the device
SIMATIC IPC627D/827D
16 Operating Instructions, 09/2014, A5E32990859-AB
PROFINET status display
Display
Meaning
LED
Description
SF
PROFINET, op-
tional
Status display for CP
1616 onboard
OFF
CP not available
CP disabled
No error, communication
established
Download in progress
Slow flashing
Link status error
IO controller: IO device cannot
be addressed
IO controller: Duplicate IP
address
Fast flashing Exception error: Diagnostics via
Web or SNMP no longer possible
AN
Diagnostic information
available
No communication
established.
Virtual status displays
The two "virtual" CP 1616 LEDs can only be seen in the SIMATIC software and can be scanned via
SNMP.
PROFINET Virtual LEDs
RUN
CP is active
STOP
CP is in the stop state
Flashes There are no "slow flashing" or
"fast flashing" states.
See also
Industry Automation and Drive Technologies - Homepage
(http://www.siemens.com/automation/service&support)