Installing and connecting the device
3.2 Installing the device
SIMATIC IPC627D/827D
30 Operating Instructions, 09/2014, A5E32990859-AB
Instructions for wall mounting
Mounting examples
Material
Hole diameter
Mounting
Concrete 8 mm diameter,
60 mm depth
Dowel: 8 mm diameter, 50 mm length
screws 4.5-6 x 50 mm
Plasterboard
(at least 13 mm
thick)
14 mm diameter Tilting dowel: 4 mm diameter,
at least 50 mm long
Metal
(at least 2 mm thick)
5 mm diameter Metal screws: 4 mm diameter,
at least 15 mm long
WARNING
Personal injuries or material damage in the case of insufficient load-bearing capacity of wall
The device could fall if the wall to which it is mounted has insufficient load-bearing capacity.
This can result in personal injuries or material damage.
Ensure that the wall is capable of bearing four times the total weight of the device (including
the brackets and expansion modules). The total weight of the device is approximately 7 kg.