Quick Guide
S7-300 Programmable Controller Hardware and Installation
A5E00105492-01
2-3
Table 2-7 CPU performance
Information on ... is available in ...
Which is the most adequate memory setup for my
application?
Reference manual CPU Data
How do I install and remove Micro Memory Cards? Chapter Commissioning; Removing/Installing Micro
Memory Cards, in the Installation Manual
Which CPU meets my requirements on
performance ?
Instruction List; Reference Manual CPU Data
How long are CPU response and processing
times?
Reference manual CPU Data
Which technological functions are implemented? Manual Technological functions
How can I use these functions? Manual Technological functions
Table 2-8 Communications
Information on ... is available in ...
Which principles do I have to take into account? Manual Communication with SIMATIC
Which options and resources does the CPU offer? Reference manual CPU Data
How do I optimize communication with the help of
communication processors (CPs)?
the respective device Manual
Which communication network is most suitable for
my application?
Chapter Configuring; Configuring subnets, in the
Installation Manual
Manual Communication with SIMATIC
How do I network the specific modules? Chapter Configuring and wiring, in the Installation
Manual
Table 2-9 Software
Information on ... is available in ...
Which software do I require for my S7-300 system? Chapter Technical data; Reference Manual CPU
data
Table 2-10 Supplementary features
Information on ... is available in ...
How do I implement operator control and
monitoring?
(Human Machine Interface)
for text displays: the respective device manual
for operator panels: the respective device manual
for WinCC: the respective device manual
How can I integrate process control modules? for PCS 7: the respective device manual
What are the options of redundant and fail-safe
systems?
Manual S7-400H - Redundant systems; Manual
Fail-safe systems
Cross-reference
Please note that you can also download respective current manuals from our public
Internet URL. Details are found in the Preface.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)