EasyManuals Logo

Siemens SIMATIC S7-300 Module data Hardware And Installation Manual

Siemens SIMATIC S7-300 Module data
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
Configuring
S7-300 Programmable Controller Hardware and Installation
A5E00105492-01
4-7
4.4 Arranging modules on a single module rack
One or multiple module racks?
The answer to this query is based on the nature of your application. Reasons for
using a single module rack could be:
Compact, space-saving module application
Central module application
Low volume of signals to be processed
Possible reasons for a distribution to multiple module racks:
High volume of signals to be processed
No more slots available
Tip: If you choose installation on a single module rack, insert a dummy module to
the right side of the CPU (Order No.: 6ES7 370-0AA01-0AA0). This gives you the
option of inserting a second module rack for your application in the future, simply
by replacing the dummy module with an interface module and without having to
reinstall and rewire the first module rack.
Rules: Arranging modules on a single module rack
The following rules apply to single-rack module installations:
No more than eight modules (SM, FM, CP) may be installed to the right side of
the CPU.
The total current load on the S7 backplane bus of all modules mounted on a
single module rack must not exceed
1.2 A (except with CPU 312C or CPU 312 IFM)
0.8 A with CPU 312C or CPU 312 IFM
The power consumption of modules ...
can be found in their technical data, e.g. S7-300 Module Data Reference Manual.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)