Principles of analog modules
5.1 Representation of the values for analog input channels
S7-300 Module data
Manual, 06/2017, A5E00105505-AJ
269
Table 5- 15 Representation of the analog values of Ni 100, 120, 200, 500, 1000 and
LG-Ni 1000 resistance thermometers
Ni x00 cli-
matic in °C
(1 digit =
0.01 °C)
Ni x00 cli-
matic in °F
(1 digit =
0.01 °F)
295.00
:
250.01
29500
:
25001
733C
H
:
61A9
H
327.66
:
280.01
32766
:
28001
7FFE
H
:
6D61
H
Overshoot range
250.00
:
25000
:
61A8
H
:
H
280.00
:
28000
:
6D60
H
:
H
Rated range
-60.01
:
-6001
:
E88F
H
:
-76.01
:
-7601
:
E24F
H
:
Undershoot range
H
H
Representation of the analog values of Ni 100 GOST Standard resistance thermometers
Table 5- 16 Representation of the analog values of Ni 100 GOST Standard resistance thermometers
Ni 100
GOST
Standard
in °C (1
digit =
0.1°C)
Ni 100
GOST
Standard in
°F (1 digit =
0.1 °F)
212.4
:
2124
:
084C
H
:
H
414.3
:
4143
:
102F
H
:
H
Overshoot range
180.0
:
1800
:
0708
H
:
356.0
:
3560
:
0DE8
H
:
Rated range
-60.1
:
-601
:
FDA7
H
:
H
-76.1
:
-761
:
FD07
H
:
H
Undershoot range
H
H