Measuring unit required
2-channel vibration measuring unit
Frequency bandwidth: 10 Hz to 1000 Hz
The measuring unit must be equipped with a function to analyze orders of frequency
components. Using this function, you can display the imbalance (1st order vibration
component).
Mechanical properties
4.9Balancing
1PH8 SIMOTICS M main motors