Figure9-3 Principle of cable routing in a wet/moist environment
9.3.4 Power connection
WARNING
Thermally damaged connecting cables
If connection cables have a conductor cross section that is too small for the application, the
connection cables can be thermally damaged. This can result in personal injury and damage to
property due to electric shock and re hazard.
• Carefully observe the current which the motor draws for your particular application!
Adequately dimension the connecting cables according to IEC 60204-1 or IEC 60364-5-52.
/
/
/
8
9
:
0RWRU
(QGVOHHYHVLQDFFRUGDQFHZLWK',1
Figure9-4 Power cable
Electrical connection
9.3System integration
1PH8 SIMOTICS M main motors
228 Conguration Manual, 12/2022, A5E51895839A