Note
For water-cooled induction motors with shaft heights 180, 225 and 280, the characteristic order
"4" is not shown. As a consequence, these motors do not have a fourth rated operating point for
"ALM 480 V" on the motor rating plate. When conguring the "ALM 480 V" line infeed, use the
data of the characteristic order "3".
Within the characteristic for SINAMICS, 3 AC 400V, ALM (2nd order, see table), 2 (sometimes
also 3) dierent rated speeds are listed. The rated speeds that are additional to the rst rated
speed stated are termed ancillary rated points and enable conguration for extended eld
weakening operation. This type of conguration is often used for main-spindle applications
Conguration
6.3Dierent rated points for induction motors
1PH8 SIMOTICS M main motors
Conguration Manual, 12/2022, A5E51895839A 213