M
max1
Nm Maximum permissible short-time torque for Motor Module Booksize
M
max2
Nm Maximum permissible short-time torque for Motor Module Booksize Combi
M
max3
Nm Maximum permissible short-time torque for Motor Module Booksize Combi
(upgrade)
P
max1
Nm Maximum permissible short-time power for Motor Module Booksize
P
max2
Nm Maximum permissible short-time power for Motor Module Booksize Combi
P
max3
Nm Maximum permissible short-time power for Motor Module Booksize Combi
(upgrade)
f
cycle
kHz Rated pulse frequency
Note
Parameters must be adapted when commissioning
Motors with the "Premium Performance" bearing version are presently not plug & play
components. Even after automatically commissioning the motors with DRIVE-CLiQ, the
commissioning engineer must adapt the appropriate parameters.
Example: Motors with V and W winding versions (10th position of the Article No.) require an
8 kHz pulse frequency. Presently, this value is not automatically set. Further, for these motors,
the current controller must be adapted. These parameters are currently not saved in the DRIVE-
CLiQ interface data and must be modied manually by the commissioning engineer. These
motors may only be operated with a fast current controller (p1810.11=yes) when connected to
the SINAMICS S120 drive system.
Request the commissioning specications from Technical Support to obtain a precise
commissioning procedure (see Chapter "Instructions").
Conguration
6.5Conguration for 1PH808 Premium Performance
1PH8 SIMOTICS M main motors
Conguration Manual, 12/2022, A5E51895839A 217