NOTICE
Frost damage to water-cooled motors
Water-cooled motors can be damaged by frost
Remove the liquid coolant before storage and blow out the cooling ducts with compressed
air.
Preserve the free shaft ends, sealing elements, and 󹪞ange surfaces with a protective coating.
NOTICE
Seizure damage to bearings
If the motors are stored incorrectly, bearing seizure damage can occur, e.g. brineling, as a result
of vibration.
Comply with the storage conditions.
Storage conditions
Please observe the warning instructions on the packaging and labels.
Store the motor in a dry, dust-free, and vibration-free indoor storage facility.
Adhere to the following values:
v
rms
< 0.2mm/s
Max. temperatures: -15°C to 55°C
Mean relative humidity < 60%
Note
Replacing roller bearings
Even if the motor was stored for more than two years under favorable conditions (i.e. in a dry,
dust-free room that is not susceptible to vibration), you must replace the bearings.
If the motor was stored under unfavorable conditions, you must replace the bearings after
approx. 18 months.
Note
Observing the notes
Observe the information in the operating instructions when storing the motor.
Preparing for use
1PH8 SIMOTICS M main motors
222 Con󹪝guration Manual, 12/2022, A5E51895839A

Table of Contents

Other manuals for Siemens SIMOTICS M-1PH8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS M-1PH8 and is the answer not in the manual?

Siemens SIMOTICS M-1PH8 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS M-1PH8
CategoryEngine
LanguageEnglish

Related product manuals