Note
Signal connection for special orders
The signal connection may di󹪜er from the standard layout in the case of special orders.
For the device version without speed encoder, there is an M16 x 1.5 connection thread.
Power connector connection
Use connector size 1.5.
Assign the connector as shown in the "Power connector 1.5" diagram. Connect the protective
conductor.
&RQQHFWRUVL]H
*1<(
8
9
:
Figure9-21 Power connector, size 1.5 (view of connector pins)
Connector Rotation range Maximum torque
Connector size 1.5 270° 20 Nm
Note
Rotating the connectors
The permissible rotation range must not be exceeded.
In order to guarantee the degree of protection, max. 10 revolutions are permissible.
Connectors should be rotated using the matching mating connector located on the
connector thread. Only rotate the Sensor Module by hand. The use of pipe wrenches,
hammers, or similar is not permitted.
Electrical connection
9.3System integration
1PH8 SIMOTICS M main motors
Con󹪝guration Manual, 12/2022, A5E51895839A 239

Table of Contents