Note
For 1PH8 motors, shaft height 80, always switch on the separately driven fan via a power
connector, even if the motor power connection is established via a terminal box.
8
9
*1<(
:
Figure9-28 Connecting the separately driven fan, shaft height 100 up to shaft height 132
Note
Rotating the connectors
Do not exceed the permissible rotation range.
In order to guarantee the degree of protection, max. 10 revolutions are permissible.
When turning, only use the mating connector that matches the connector thread. Only
rotate Sensor Modules by hand. Do not use any tools such as pipe wrench, hammer or similar
tool.
Connector Rotation range Maximum rotation torque
Connector size 1.0 270° 12Nm
Note
Scope of delivery
The mating connector is not included in the scope of delivery.
Article number mating connector size 1 (with full thread) 6FX2003-0LU00