Descriptions Data position in Article No.
1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z
Power connector
(top)
9) 12)
NDE Left G
Power connector
(top)
9) 12)
DE Left H
Version
Without a DRIVE-CLiQ interface, PT1000 temperature sensor in the stator winding 2
With a DRIVE-CLiQ interface 1
Special version (order codes are
required for options)
Z
1) Only possible if the 8th data position is "1" (induction version)
2) Limited to n
max
= 12,000r/min
3) Limited to n
max
= 9000 r/min
4) Limited to n
max
= 4600r/min
5) Limited to n
max
= 15,000r/min
6) Only possible for shaft height 100, 132, and 160.
7) Only possible if 8th data position is "1" (induction version)
Shaft height 80: Limited to n
max
= 15,000r/min
shaft height 100: Limited to n
max
= 12,000r/min
shaft height 132: Limited to n
max
= 10,000r/min
shaft height 160: Limited to n
max
= 9000r/min, not possible if 12th data position is "2" (IM B5)
8) Limited to n
max
= 5000r/min, shaft height 132: n
max
= 4500r/min, shaft height 160: n
max
= 4000r/min
9) For a shaft height of 100, a power connector is only possible up to a maximum stall current of Io = 36A,
for a shaft height of 132, a power connector is only possible up to a maximum stall current of Io = 85A,
a power connector is not possible for shaft height 160
10) Only possible if 14th data position: L, M
11) Not possible if 14th data position: M
12) Not possible for motors in a star-delta (wye-delta) circuit if the 10th data position is "S"
13) Only possible if 8th data position is "1" (induction version)
Shaft height 80: Limited to n
max
= 20,000r/min
shaft height 100: Limited to n
max
= 18,000r/min
shaft height 132: Limited to n
max
= 15,000r/min
shaft height 160: Limited to n
max
= 10,000r/min, not possible if 12th data position is "2" (IM B5)
14) Not possible with shaft height 160 and 14th data position: L, M
15) Not possible if 9th data position: T, U
16) Not possible with shaft height 160 and 8th data position is "2" or "4" (synchronous version).
17) Limited to shaft height 100: n
max
= 7000r/min, shaft height 132: n
max
= 6500r/min, shaft height 160: n
max
= 5300r/min
18) Only possible for the 9th data position: A, C, and S
Motor description
3.4Selection and ordering data
1PH8 SIMOTICS M main motors
Conguration Manual, 12/2022, A5E51895839A 39