Descriptions Data position of the order No.
1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z
Bearings Vibration severity
acc. to
Siemens/EN
60034-14
Shaft and ange ac‐
curacy
Standard with lo‐
cating bearing
R/A R B
Standard with lo‐
cating bearing
S/A R C
Standard with lo‐
cating bearing
SR/A R D
Increased radial
forces
R/A R F
Power connec‐
tion
Cable entry Signal connection (looking onto DE)
Terminal box
(top)
Right DE A
Terminal box
(top)
Left DE B
Terminal box
(top)
NDE Left C
Terminal box
(top)
1)
DE Left D
Version
With a DRIVE-CLiQ interface 1
Without a DRIVE-CLiQ interface, PT1000 temperature sensor in the stator winding 2
Special version (order codes are required for options) Z
1) Not possible for gk874 terminal boxes (1PH816 and 1PH8138-xxG2x)
Motor description
3.4Selection and ordering data
1PH8 SIMOTICS M main motors
Conguration Manual, 12/2022, A5E51895839A 43