Shaft height Flow
rate, min.
l/min
Pressure drop
bar
Sound pressure level L
pA
(1 m)
Motor rated load,
tolerance +3 dB
dB
Thread con‐
nection at
NDE
Inch
180 (1PH8184) 15 0.6 70
2)
G 3/8
180 (1PH8186) 15 0.7 G3/8
225 (1PH822.-1)
(asynchronous)
20 0.6 G 3/8
225 (1PH822.-2)
(synchronous)
25 0.9 70
3)
G 3/8
280 35 0.6 72
3)
G 1/2
1) For a rated pulse frequency of 4 kHz and speed range up to 5000 r/min
2) For a rated pulse frequency of 2 kHz or 4 kHz and speed ranges for
SH 180 of up to 5000 r/min
SH 225 up to 4500 r/min
3) For a rated pulse frequency of 2 kHz and speed ranges for
SH 225 of up to 4500 per r/min
SH 280 up to 3300 r/min
Heat loss to be dissipated
The values for the heat loss to be dissipated are specied according to the rated point in Chapter
"Technical tables and characteristics."
Water specication
Cooling water quality
The values specied for the cooling water correspond to the requirements for a closed
cooling circuit. Not all specied concentrations will occur in the cooling water at the same
time.
A lter can be used to ensure smooth operation. The grade of ltration should be no less than
100μm.
Cooling water inlet temperature
The maximum cooling water inlet temperature is 30°C (86 °F)
Cooling water specications
Table 4-12 Cooling water specications (SH 80 to 160)
Component Quality of the water used as coolant for motors with stain‐
less steel pipes + cast iron or steel jacket
pH value 6 ... 9
Total hardness < 170ppm
Electrical conductivity < 500μS/cm
Chloride ions < 40ppm, can be achieved by adding deionized water.
Sulfate ions < 50ppm
Mechanical properties
4.1Cooling
1PH8 SIMOTICS M main motors