Diagnostics
5.4 Fault and alarm messages
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
185
5.4.6
Function diagrams and parameters
Overview of important function diagrams (see SINAMICS S120/S150 List Manual)
8050
Diagnosis
- Overview
8060
Diagnostics
- fault buffer
8065
Diagnostics
- alarm buffer
8070
Diagnostics
- faults/alarms trigger word (r2129)
8075
Diagnostics
- faults/alarms configuration
8134
Diagn
ostics - measuring sockets (T0, T1, T2)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
r0944
CO: Counter for fault buffer changes
p0952
Fault cases, counter
p2038
IF1 PROFIdrive STW/ZSW interface mode
p2100[0...19]
Changing the
fault reaction, fault number
r2139.0...15
CO/BO: Status word, faults/alarms 1
p3116
BI: Suppress automatic acknowledgment
r3120[0...63]
Component fault
r3121[0...63]
Component alarm
r3122[0...63]
Diagnostic attribute fault
r3123[0...63]
Diagnostic at
tribute alarm