Commissioning
4.3 Creating a project
Commissioning with Startdrive
70 Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
4.3.4.4
Editing a DRIVE-CLiQ connection
DRIVE-CLiQ connections
Blue lines are used to visualize the DRIVE-CLiQ connections between the various
components. The connections must be created in accordance with the real wiring in the
offline project.
When creating a component, the connections are drawn with the default settings. You must
manually correct the connections in the device view if your real wiring deviates from this.
Working with DRIVE-CLiQ connections is explained using an infeed unit as example. The
procedure is identical for all other components.
Deleting a Drive-CLiQ connection
Delete a DRIVE-CLiQ connection if you no longer require it.
1. Right click on the DRIVE-CLiQ connection. A shortcut menu is opened.
Figure 4-15 Deleting a Drive-CLiQ connection
2. To remove the DRIVE-CLiQ component, select "Delete" from the shortcut menu.
The connection is deleted.