Startdrive commissioning tool
2.4 User interface - trace function
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
41
Project navigator
Management and creation of the trace and measurements directly in the project tree and via context menu commands.
Working area
Trace toolbar
Icons for managing the trace in the project and device:
Activation/deactivation of installed traces
Deletion of installed traces
Transferring trace configurations and measurements between the device and project
Exporting trace configurations and measurements
Switchover between offline and online display
Status display of the trace
Display of the current status of the recording. The status is displayed only in online mode.
Configuration tab
Device-specific configuration of the trace duration, trigger condition and signal selection.
Diagram tab
Display of the recorded values as a curve diagram and the signal sources from the displayed measurement.
"Trace" tab
Display of the measurement cursor data and snapshots.
Inspector window
Display of general information regarding the trace configuration
Figure 2-9 Trace interface
See also