Commissioning
4.3 Creating a project
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
85
Assignment of measuring system to Sensor Modules
SMC
SME
Measuring systems
SMC10
SMC20
SMC30
SMC40
1)
SME20
SME25
SME120
SME125
Resolver Yes - - - - -
Incremental enco-
der sin/cos (1Vpp)
with zero pulse
- Yes - - Yes - Yes
Incremental encod-
er sin/cos (1Vpp)
without zero pulse
- Yes - - Yes Yes Yes Yes
EnDat absolute
encoder
- Yes - Yes - Yes Yes
Incremental En-
coder TTL/HTL
- - Yes - - -
SSI absolute en-
coder
2)
- - Yes - - -
Temperature eval-
uation
Yes Yes Yes - - - Yes (gal-
vanically
isolated)
Yes (gal-
vanically
isolated)
1)
Only for direct measuring systems.
2)
Only as of article number 6SL3055-0AA00-5CA1
Additional information
You can find additional information about the Sensor Modules in the "Control Units and
Additional System Components" manual and in the Startdrive online help.