11.03 6 Alarms
6.1 Alarms for SINUMERIK 840digital
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
6-315
11: Upper limit value SE1. Enter equal MDs.
12: Lower limit value SE1. Enter equal MDs.
13: Upper limit value SE2. Enter equal MDs.
14: Lower limit value SE2. Enter equal MDs.
15: Safe cam 1+ (+tolerance). Enter equal MDs.
16: Safe cam 1+. Enter equal MDs.
17: Safe cam 1- (+tolerance). Enter equal MDs.
18: Safe cam 1-. Enter equal MDs.
19: Safe cam 2+ (+tolerance). Enter equal MDs.
20: Safe cam 2+. Enter equal MDs.
21: Safe cam 2- (+tolerance). Enter equal MDs.
22: Safe cam 2-. Enter equal MDs.
23: Safe cam 3+ (+tolerance). Enter equal MDs.
24: Safe cam 3+. Enter equal MDs.
25: Safe cam 3- (+tolerance). Enter equal MDs.
26: Safe cam 3-. Enter equal MDs.
27: Safe cam 4+ (+tolerance). Enter equal MDs.
28: Safe cam 4+. Enter equal MDs.
29: Safe cam 4- (+tolerance). Enter equal MDs.
30: Safe cam 4-. Enter equal MDs.
31: Position tolerance. Enter equal MDs.
32: Reference position tolerance. Enter equal MDs.
33: Time, speed changeover. Enter equal MDs.
34: Tolerance time SGE changeover. Enter equal MDs.
35: Delay time, pulse cancellation. Enter equal MDs.
36: Time to test the pulse cancellation. Enter equal MDs.
37: Transition time, STOP C to SBH. Enter equal MDs.
38: Transition time, STOP D to SBH. Enter equal MDs.
39: Transition time, STOP E to SBH. Enter equal MDs.
40: Stop response after SG. Enter equal MDs.
41: Stop response after SE. Enter equal MDs.
42: Shutdown speed after pulse cancellation. Enter equal MDs.
43: Data save test, stop response.
44: Actual position value + limit value SG1.
45: Actual position value - limit value SG1.
46: Actual position value + limit value SG2.
47: Actual position value - limit value SG2.
48: Actual position value + limit value SG3.
49: Actual position value - limit value SG3.
50: Actual position value + limit value SG4.
51: Actual position value - limit value SG4.
52: Standstill position + tolerance.
53: Standstill position - tolerance.
54: Actual position value "+ nx" + tolerance.
55: Actual position value "+ nx".
56: Actual position value "- nx".
57: Actual position value "- nx" + tolerance.
58: Actual stop request.
59: SG correction factor 1. Enter equal MDs.
60: SG correction factor 2. Enter equal MDs.
61: SG correction factor 3. Enter equal MDs.
62: SG correction factor 4. Enter equal MDs.
63: SG correction factor 5. Enter equal MDs.
64: SG correction factor 6. Enter equal MDs.
65: SG correction factor 7. Enter equal MDs.
66: SG correction factor 8. Enter equal MDs.
67: SG correction factor 9. Enter equal MDs.
68: SG correction factor 10. Enter equal MDs.
69: SG correction factor 11. Enter equal MDs.
70: SG correction factor 12. Enter equal MDs.
71: SG correction factor 13. Enter equal MDs.