11.03 6 Alarms
6.1 Alarms for SINUMERIK 840digital
© Siemens AG 2003 All Rights Reserved
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
6-337
27222
PROFIsafe: S7 F module PROFIsafe address %1 unknown
Parameter %1 = PROFIsafe address
Explanation The F module with the specified PROFIsafe address has not been
parameterized as an F module in the NCK MD.
Response Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Check the S7 PROFIBUS configuration. Register the module in the NCK MD.
Program continuation Power-down the control and power-up again.
27223 PROFIsafe: NCK F module MD %1[%2] is not a %3 module
Parameter %1 = MD name
%2 = MD field index
%3 = Module type
Explanation The F module parameterized in the specified NCK MD has not been designated
as an appropraite input/output module in the S7 PROFIBUS configuration.
- %3 = INPUT: - NCK F parameterization expects an INPUT module
- %3 = OUTPUT: NCK F parameterization expects an OUTPUT module
- %3 = IN/OUT: NCK F parameterization expects an INPUT or OUTPUT
module
Response Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Check the module in the S7 PROFIBUS configuration
Program continuation Power-down the control and power-up again.
27224 PROFIsafe: F module MD %1[%2] - MD %3[%4]: Double
assignment of PROFIsafe address
Parameter %1 = MD name 1
%2 = MD field index 1
%3 = MD name 2
%4 = MD field index 2
Explanation In the NCK MD or in the S7 F parameters, the same PROFIsafe address has
been parameterized for the F modules parameterized in the specified machine
data. This means that there is no unique communications relationship possible
between the F master and F slave.
Response Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Check and correct the S7 F parameterization and NCK MD.
Program continuation Power-down the control and power-up again.