6 Alarms 11.03
6.1 Alarms for SINUMERIK 840digital
© Siemens AG 2003 All Rights Reserved
6-338 SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
27225
PROFIsafe: Slave %1, configuration error, %2
Parameter %1 = PROFIBUS slave address
%2 = Configuration error
Explanation An error occurred during the evaluation of the S7 PROFIBUS configuration for
the specified slave. This is specified further in the alarm parameter.
%2 = PRM header: the PRM telegram for this slave could not clearly be
interpreted.
Response Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy Check the S7 PROFIBUS configuration and correct.
Program continuation Power-down the control and power-up again.
27240 PROFIsafe: DP M has not run-up, DP info: %1
Parameter %1 = actual information from the DP interface NCK-PLC
Explanation There is no DP configuration available to the NCK after the time specified via
the MD $MN_PLC_RUNNINGUP_TIMEOUT.
Response Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy - increase MD $MN_PLC_RUNNINGUP_TIMEOUT
- check the PLC operating state
- check the PLC operating system software release
- delete the F parameterization in the NCK-MD.
Program continuation Power-down the control and power-up again.
27241 PROFIsafe: DP M version different, NCK: %1, PLC: %2
Parameter %1 = version of the DP interface on the NCK side
%2 = version of the DP interface on the PLC side
Explanation The DP interface has been implemented differently for the NCK and PLC
components. The F communication cannot be initialized.
Response Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Remedy - check PLC operating system and correct NCK software versions.
- upgrade the PLC operating system.
- delete NCK-F parameterization.
Program continuation Power-down the control and power-up again.
27242 PROFIsafe: F module %1, %2 faulty
Parameter %1 = PROFIsafe address
%2 = incorrect F parameter
Explanation An error was detected during the evaluation of the F parameters.
%2 = CRC1: CRC error, F parameters.
%2 = F_WD_Timeout: The monitoring time parameterized in Step 7 is too short

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals