Procedure
Proceed as follows to configure the PROFINET interface of the SINUMERIK MC:
1. In the network view, click the PLC in the basic rack of the SINUMERIK MC.
2. In the secondary navigation of the inspector window, select menu "Properties > General".
You can configure the IP addresses of the various PROFINET interfaces in the associated
properties:
– PROFINET interface [X150]
– PROFINET interface [X160]
Figure 2-11 PROFINET interface
3. Under "IP protocol", in each case check as to whether the correct IP address is set
("192.168.0.1" for X150 in the example).
Fundamentals
2.8 Device configuration
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB 43