Telegram
Process data
701
SLS setpoint speed limiting (32 bit)
S_V_LIMIT_B (Page 378)
PZD3…4
Safety Info Channel status word 3
S_ZSW3B (Page 377)
PZD5
10.5.2 PROFIsafe process data
10.5.2.1 Note
Note
Additional information in the function block diagrams
Generally, for the subsequent descriptions, reference is made to a function block diagram. You
can find the function block diagram mentioned in the SINAMICS S120/S150 List Manual.
Note
Reserved control/status bits
A series of control and/or status bits are listed as reserved in the following tables. The reason
for this is that various Safety Integrated Functions will only be implemented at a later point in
time. The bits are reserved for future functions.
Data descriptions
10.5 Process data
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB 359