EasyManua.ls Logo

Siemens SINUMERIK MC - S_ZSW2: Safety Status Word 2

Siemens SINUMERIK MC
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Byte Bit Meaning Remarks
3 0 Select gearbox stage, bit 0 Select gearbox stage (3 bits)
1 Select gearbox stage, bit 1
2 Select gearbox stage, bit 2
3 Gearbox stage switchover 1 With increased position tolerance
0 Without increased position tolerance
4 SS2E 1 Deselect SS2E
0 Select SS2E
5 SS2ESR 1 Deselect SS2ESR
0 Select SS2ESR
6, 7 Reserved
1)
Signals not relevant for Extended Functions: Must not be evaluated.
10.5.2.5 S_ZSW2: Safety status word 2
S_ZSW2 (Basic Functions)
Safety status word 2 (S_ZSW2)
S_ZSW2, input signals
see function diagram [2806].
Table 10-16 Description of safety status word 2 (S_ZSW2)
Byte Bit Meaning Remarks
0 0 STO active 1 STO active
0 STO not active
1 SS1 active 1 SS1 active
0 SS1 not active
2 SS2 active 0
1)
3 SOS active 0
1)
4 SLS active 0
1)
5 Reserved
6 SLP active 0
1)
7 Internal Event 1 Internal event
0 No internal event
Data descriptions
10.5 Process data
Safety Integrated (with SINAMICS S120)
366 Commissioning Manual, 02/2020, A5E46305916B AB

Table of Contents

Related product manuals