Byte Bit Meaning Remarks
1 0 SLA active 0
1)
1 Active SLS level, bit 0 0
1)
2 Active SLS level, bit 1 0
3 Reserved
4 SDI positive active 0
1)
5 SDI negative active 0
1)
6 Reserved
7 SSM (speed) 0
1)
2 0 ... 2 Reserved
3 SLP active position range 0
1)
4, 5 Reserved
6 Safe position valid 0
1)
7 Safely referenced 0
1)
3 0 ... 2 F-DI 0 ... 2
2)
0
1)
3 SS2ESR active 0
1)
4 SS2E active 0
1)
5 SOS selected 0
1)
6 SLP upper limit maintained 0
1)
7 SLP lower limit maintained 0
1)
1)