Introduction
1.3 Characteristics
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
25
Voltage Protection
Overvoltage and undervoltage detection with different elements
Two overvoltage elements for the phase-to-ground voltages
Two overvoltage elements for the phase-to-phase voltages
Two overvoltage elements for the positive sequence voltage
Two overvoltage elements for the negative sequence system of the voltages
Two overvoltage elements for the zero system of the voltages or for any other single-phase voltage
Adjustable dropout conditions
Two undervoltage elements for the phase-to-ground voltages
Two undervoltage elements for the phase-to-phase voltages
Two undervoltage elements for the positive sequence system of the voltages
Adjustable current criterion for undervoltage protection functions
Frequency Protection 81 (Optional)
Monitoring of falling below (f<) and/or exceeding (f>) with 4 frequency limits and time delays that are inde-
pendently adjustable
Particularly insensitive to harmonics and abrupt phase angle changes
Wide frequency range (approx. 25 Hz to 70 Hz)
Automatic Reclose Function (Optional)
For reclosing after 3-pole open condition
Two reclosing attempts
With separate action times for each reclosing attempt, optionally without action times
With separate dead times
Optionally controlled by protection element pickup with separate dead times after 1-pole, 2-pole or 3-pole
pickup
Monitoring Functions
Reliability of the device is greatly increased because of self-monitoring of the internal measurement circuits,
the auxiliary power supply as well as the hardware and software
Monitoring of the current transformer and voltage transformer secondary circuits using summation and sym-
metry check techniques
Monitoring of communication with statistics showing the availability of transmission telegrams
Check of the consistency of protection settings at both line ends: no processor system start-up with incon-
sistent settings which could lead to a malfunction of the differential protection system
Trip circuit monitoring possible
Check of local and remote measured values and comparison of both
Broken wire supervision for the secondary CT circuits with fast phase segregated blocking of the differential
protection system in order to avoid malfunction
Supervision of measuring voltage failure using "Fuse Failure Monitor"