4. Signal cable screen is folded back over outer sheath and grounded beneath cable clamp.
– Field mount transmitter: Connect wires to terminals using wiring tool.
Active current output Passive current output
⑤ C ⑥ Cp-
④ Ca+ ⑤ C
Functional Earth Functional Earth
Active current output Passive current output
,VLJQDO
U
0
)&
Ca+
Cp-
C
8
LQW
+
-
,VLJQDO
8
H[W
8
Ca+
+
-
Cp-
)&
C
– Wall mount transmitter: Connect wires to terminals using wiring tool.
)
)
Active current output Passive current output
4 Ca+ 5 C
5 C 6 Cp-
5. Tighten cable gland.
Connecting
5.2 Connecting FC330
SITRANS FC330
68 Operating Instructions, 01/2019, A5E44030648-AB