11.7 Operating conditions
Table 11-23 Basic conditions
Description Specification
Ambient temperature (°C[°F])
(Humidity max. 90 %)
Operation:
Transmitter without display
Transmitter with display
-40 to +60 [-40 to +140]
-20 to +60 [-4 to +140]
Ambient temperature (°C[°F])
(Humidity max. 90 %)
Storage:
Transmitter without display
Transmitter with display
-40 to +70 [-40 to +158]
-40 to +70 [-40 to +158]
Climate class DIN 60721-3-4
Altitude Up to 2000 m (6560 ft)
Relative humidity [%] 95
EMC performance
● Emission
● Immunity
● EN 55011 / CISPR-11
● EN/IEC 61326-1 (Industry)
NAMUR NE 21
Table 11-24 Cleaning and sterilizing conditions
Description Specification
Cleaning method
● CIP
● SIP
Cleaning temperature On request
Cleaning frequency On request
Cleaning duration On request
Table 11-25 Process media conditions
Description Specification
Process media temperature (T
s
) (min to max) [°C (F)]
● DIN11851/ SMS1145/ DIN32676
Process media temperature (T
s
) (min to max) [°C (F)]
● DN15 - DN150
-10 to +140
-50 up to +205 (-58 to +401)
Process media density (min to max) [kg/m
3
(lb/ft
3
] 1 to 5000 (0.06 to 312)
Process media gauge pressure (min to max) [bar (psi)] 0 to 100 (0 to 1450)
Process media absolute pressure (min to max) [bar (psi)] Stainless steel: 1 to 101 (14.5 to 1465)
Process media viscosity Gases and non-compressible liquids
Pressure drop See Siemens Sizing & Calculation tool
(www.siemens.com/pisizer). Select
"Flow" > "SITRANS F C sizing".
Pressure temperature ratings See "Pressure - temperature ratings"
(Page 211)
Technical data
11.7 Operating conditions
SITRANS FC330
204 Operating Instructions, 01/2019, A5E44030648-AB