EasyManua.ls Logo

Siemens SITRANS Series - Page 207

Siemens SITRANS Series
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Long-term stability at ±30 °C (±54 °F) - differential pressure and flow
250 mbar/25 kPa/3.63 psi
600 mbar/60 kPa/8.70 psi
1600 mbar/160 kPa/23.21 psi
5 bar/500 kPa/72.52 psi
In 5 years ≤ (0.125 • r)%
In 10 years ≤ (0.15 • r)%
30 bar/3 MPa/435.11 psi In 5 years ≤ (0.25 • r)%
In 10 years ≤ (0.35 • r)%
Step response time T
63
(without electrical damping) - - differential pressure and flow (PN160)
20 mbar/2 kPa/0.29 psi Approx. 0.160 s
60 mbar/6 kPa/0.87 psi Approx. 0.150 s
250 mbar/25 kPa/3.63 ps
600 mbar/60 kPa/8.70 psi
1600 mbar/160 kPa/23.21 psi
5 bar/500 kPa/72.52 psi
30 bar/3 MPa/435.11 psi
Approx. 0.135 s
Step response time T
63
(without electrical damping) - - differential pressure and flow (PN420)
250 mbar/25 kPa/3.63 psi Approx. 0.25 s
600 mbar/60 kPa/8.70 psi
1600 mbar/160 kPa/23.21 psi
5 bar/500 kPa/72.52 psi
30 bar/3 MPa/435.11 psi
Approx. 0.2 s
Effect of mounting position - differential pressure and flow
Effect of mounting position In pressure per change of angle
≤ 0.7 mbar/0.07 kPa/0.028
inH
2
O per 10° incline
(zero-point correction is possible
with position error compensation)
Technical data
13.2 Measuring accuracy of SITRANS P320
SITRANS P320/P420 (mA/HART)
Operating Instructions, 06/2018, A5E44852162-AA 207

Table of Contents

Other manuals for Siemens SITRANS Series

Related product manuals